|
Menu









Subscribe to our
free mailing list to receive occasional emails with
news about our products and event information.

Member of


|
|
Bio-Assay Detection Kits
Elite™Detection Kits for
Biochemical Assays
|
Part #
|
Description
|
Price
($US)
|
Quantity
|
| CA-A401 |
Acetylcholinesterase Assay Kit (Fluorescence) - 200 assays
Description: The Elite™
Acetylcholinesterase Assay Kit uses the outstanding Thiolite™ Green to quantify the thiocholine produced from the
hydrolysis of acetylthiocholine by AChE in blood, in cell extracts, and in other solutions. Thiolite™ Green is not
fluorescent until reacted with a thiol group. It has spectral properties similar to those of fluorescein, making
this assay compatible with almost every fluorescence instrument. The fluorescence intensity of Thiolite™ Green is
used to measure AChE activity. Compared to the existing thiol probes (e.g., mBBr and bBBr), Thiolite™ Green is much
more sensitive.
Application: The Elite™ Acetylcholinesterase Assay Kit provides an ultrasensitive
fluorometric one-step assay to detect as little as 0.01mU AChE in a 100 μl assay volume (0.1 mU/ml). The assay can be
performed in a convenient 96-well or 384-well microtiter-plate format. Its signal can be easily read by a fluorescence
microplate reader at Ex/Em = 490/520 nm.
Detection: Fluorescence microplate
reader. |
$189.00 |
|
|
CA-A051 |
Aldehyde Detection Assay Kit (Fluorescence) - 200 assays
Description: The Elite™
Aldehyde Detection kit is used for quantifying aldehydes at higher pH. This kit uses a proprietary fluorogenic dye that
generates a strongly fluorescent product upon reacting with an aldehyde. This fluorimetric kit provides a sensitive
mix-and-read method to detect as little as 0.3 nanomole of aldehyde in a 100 μl assay volume (3 μM).
Application:
The assay can be performed in a convenient 96-well or 384-well microtiter-plate
format and easily adapted to automation without a separation step. Its signal can be read by a
fluorescence microplate reader at Ex/Em = 365/435 nm.
Detection:
Fluorescence microplate reader. |
$285.00 |
|
| CA-G055 |
GSH Assay Kit (Fluorescence) - 200 assays
Description: The Elite™ Glutathione Assay Kit provides an ultrasensitive fluorimetric assay to
quantitate GSH in sample. The proprietary non-fluorescent glutathione sensor used in the kit becomes strongly green
fluorescent upon reacting with a GSH compound, which has the spectral properties almost identical to those of fluorescein
and can be easily read by a fluorescence microplate reader at Ex/Em = 490/520 nm. The kit can detect as little as 1
picomole of GSH in a 100 μL assay volume (10 nM). In addition, both absorption and emission spectra of the
glutathione adduct are pH-independent, making this assay kit highly robust.
Application: The assay can be performed in a convenient 96-well or 384-well microtiter-plate
format and easily adapted to automation without a separation step.
Detection: Fluorescence microplate reader. |
$195.00 |
|
|
CA-G056 |
GSH/GSSG Ratio Assay Kit (Fluorescence) - 200 assays
Description: There are quite a few reagents or assay kits available for quantitating thiols in
biological systems. However, all the commercial kits either lack sensitivity or have tedious protocols. The Elite™
Glutathione GSH/GSSG Ratio Assay Kit provides an ultrasensitive assay to quantitate GSH in the sample. The
kit uses a proprietary non-fluorescent dye that becomes strongly fluorescent upon reacting with GSH. With a one-step
fluorimetric method, the kit can detect as little as 1 picomole of GSH or GSSG in a 100 μl assay volume.
Application:
The assay can be performed in a convenient 96-well or 384-well microtiter-plate
format and readily adapted to automation without a separation step. Its signal can be easily read by a fluorescence microplate reader at Ex/Em = 490/520 nm.
Detection:
Fluorescence microplate reader. |
$195.00 |
|
| CA-H100 |
HDAC Activity Assay Kit (Green Fluorescence) - 200 assays in 96-well plates
Description: This kit uses our non-peptide HDAC Green™ substrate that is much more sensitive than the
peptide-based HDAC substrates such as Ac-RGK(Ac)-R110, Ac-RGK(Ac)-AMC and Ac-RGK(Ac)-AFC. In addition, HDAC Green™ substrate is
also much more resistant to protease hydrolysis than other commercial peptide-based HDAC substrates.
Application: It can be used for measuring HDAC activity in cell lysates or HDAC inhibitor
screening with cell extracts or purified enzymes.
Ex/Em: 490/520 nm.
Detection: Fluorescence microplate reader. |
$349.00 |
|
|
CA-N205 |
NADH Assay Kit (Red Fluorescence) - 400 assays in 96-well plates
Description: The Elite™ Fluorimetric NADH Assay Kit provides a sensitive, one-step assay to detect as little as 100 pico-moles of NADH in a 100
μl assay volume (1 μM). It has very low background since it is run in the red visible range that significantly reduces
the interference resulted from biological samples.
Application:
The assay can be performed in a convenient 96-well or 384-well microtiter-plate
format. Its signal can be easily read by either a fluorescence microplate reader at Ex/Em = 540/590 nm or an absorbance microplate reader at ~576 nm.
Ex/Em: 540/590 nm.
Detection: Fluorescence microplate reader. |
$349.00 |
|
| CA-N218 |
NAD/NADH Assay Kit (Red Fluorescence) - 400 assays in 96-well plates
Description: The Elite™ Fluorimetric NAD/NADH Assay Kit provides a sensitive, one-step assay to detect as little
as 10 pico-moles of NAD(H) in a 100 μl assay volume (100 nM). It has very low background since it is run in the red
visible range that significantly reduces the interference resulted from biological samples.
Application: The assay can be performed in a convenient 96-well or 384-well microtiter-plate
format and readily adapted to automation without a separation step. Its signal can be easily read by either a
fluorescence microplate reader at Ex/Em = 530-570 nm/590-600 nm (maximum Ex/Em = 540/590 nm) or an absorbance microplate
reader at ~576 nm.
Ex/Em: 540/590 nm.
Detection: Fluorescence microplate reader. |
$349.00 |
|
|
CA-N226 |
NAD/NADH Ratio Assay Kit (Red Fluorescence) - 250 assays in 96-well plates
Description: The Elite™ Fluorimetric NAD/NADH Ratio Assay Kit provides a convenient method for sensitive detection of NAD, NADH and their ratio;
there is no need to purify NAD/NADH from sample mix. It has very low background since it is run in the red visible range
that significantly reduces the interference resulted from biological samples.
Application:
The assay can be performed in a convenient 96-well or 384-well microtiter-plate format. Its signal can be easily read by either a fluorescence microplate reader at Ex/Em = 530 - 570/590 - 600 nm (maximum Ex/Em = 540/590 nm) or an absorbance
microplate reader at ~576 nm. This kit provides NAD and NADH extraction buffer, and cell lysis buffer for your
convenience. It has been frequently used for determining NAD/NADH from cell lysates.
Ex/Em: 540/590 nm.
Detection: Fluorescence microplate
reader. |
$399.00 |
|
| CA-N405 |
NADPH Assay Kit (Red Fluorescence) - 400 assays in 96-well plates
Description: The Elite™ Fluorimetric NADPH Assay Kit
provides a sensitive, one-step assay to detect as little as
100 picomoles of NADPH in a 100 μl assay volume (1 μM). It
has very low background since it is run in the red visible
range that significantly reduces the interference resulted
from biological samples.
Application: The assay can be
performed in a convenient 96-well or 384-well microtiter-plate
format. Its signal can be easily read by either a
fluorescence microplate reader at Ex/Em = 540/590 nm or an
absorbance microplate reader at ~576 nm.
This kit has been used for screening enzyme activities that
use NADP/NADPH as a cofactor. It has also been used for the
sensitive detection of NADPH in cell-based assays. Compared
to the other commercial kits, this assay has higher
signal/background ratio.
Ex/Em: 540/590 nm.
Detection: Fluorescence microplate
reader. |
$349.00 |
|
|
CA-N418 |
NADP/NADPH Assay Kit(Red Fluorescence) - 400 assays in 96-well plates
Description: The Elite™
Fluorimetric NADP/NADPH Assay Kit provides a sensitive,
one-step assay to detect as little as 1 picomoles of NADPH
in a 100 μl assay volume (10 nM). It has very low background
since it is run in the red visible range that significantly
reduces the interference resulted from biological
samples.There is no need to purify NADP/NADPH from sample
mix.
Application:
The assay can be
performed in a convenient 96-well or 384-well microtiter-plate
format. Its signal can be easily read by either a
fluorescence microplate reader at Ex/Em = 540/590 nm or an
absorbance microplate reader at ~576 nm.
Ex/Em: 540/590 nm.
Detection: Fluorescence microplate
reader. |
$399.00 |
|
| CA-N426 |
NADP/NADPH Ratio Assay Kit (Red Fluorescence) - 250 assays in 96-well plates
Description: This Elite™ Fluorimetric NADP/NADPH
Ratio Assay Kit provides a convenient method for sensitive
detection of NADP, NADPH and their ratio. The enzymes in the
system specifically recognize NADP/NADPH in an enzyme
recycling reaction that significantly increases detection
sensitivity. In addition, this assay has very low background
since it is run in the red visible range that considerably
reduces the sample interference.
Application: The assay can be
performed in a convenient 96-well or 384-well microtiter-plate
format. Its signal can be easily read by either a
fluorescence microplate reader at Ex/Em = 540/590 nm or an
absorbance microplate reader at ~576 nm.
Ex/Em: 540/590 nm.
Detection: Fluorescence microplate
reader. |
$395.00 |
|
|
CA-C315 |
cAMP ELISA Assay Kit(Fluorescence) - 1 plate (96-well)
Description: Elite™ cAMP ELISA
Assay Kit provides the sensitive method for detecting
adenylate cyclase activity in biochemical or cell-based
assay system. Compared to other ELISA cAMP assay kits, our
kit eliminates the tedious acetylation step. The kit uses
Amplite™ Red as a fluorimetric substrate to quantify the HRP
activity.
Application:
The assay can be
performed in a convenient 96-well or 384-well microtiter-plate
format and easily adapted to automation. The fluorescent
product formed is proportional to the activity of HRP-cAMP
conjugate.
Detection: Fluorescence microplate
reader. |
$299.00 |
|
-
Ordering Instructions -
Elite™ Detection Kits for Cell Based Assays
|
Part #
|
Description
|
Price
($US)
|
Quantity
|
| CA-C061 |
Caspase Activity Assay Kit (Green Fluorescence) - 100 assays
Description: It provides all the essential
components with an optimized assay protocol. It is designed
to detect cell apoptosis by measuring generic activation of
caspases (caspase-1, -3, -4, -5, -6, -7, -8 and -9) in live
cells.
Application: Used for either the
quantification of most activated caspase activities in
apoptotic cells or screening of caspase inhibitors.
Ex/Em: 488/520 nm.
Detection: Flow cytometer. |
$299.00 |
|
|
CA-C150 |
Caspase 3/7 Assay Kit (Green Fluorescence) - 2 plates (96-well)
Description: This Kit uses
(Z-DEVD)2 R110 as fluorogenic indicator for assaying caspase
3/7 activity. R110-derived caspase substrates are probably
the most sensitive indicators used for the fluorimetric
detection of various caspase activities.
Application:
It can be used
to continuously measure the activities of caspase 3/7 in
cell extracts and purified enzyme preparations with a
fluorescence microplate reader or fluorometer.
Ex/Em: 490/520 nm.
Detection:
Fluorescence microplate
reader. |
$299.00 |
|
| CA-C158 |
Caspase 8 Assay Kit (Fluorescence) - 2 plates (96-well)
Description: Caspase 8 is proven to have
substrate selectivity for the peptide sequence
Ile-Glu-Thr-Asp (IETD). This kit uses (Ac-IETD)2-R110 as a
fluorogenic indicator for caspase 8 activity. Cleavage of
rhodamine 110 (R110) peptides by caspase 8 generates
strongly fluorescent R110 which is monitored at the emission
between 520 nm and 530 nm with the excitation between 480 nm
and 500 nm. This spectral feature makes the kit compatible
with the FITC filter set.
Application: The Elite™ Caspase 8
Assay Kit provides all the essential components with an
optimized assay protocol. The assay can be readily adapted
for high throughput screenings. It can be used to either
quantify the activated caspase 8 activities in apoptotic
cells or screen the caspase 8 inhibitors.
Detection:
Fluorescence microplate
microplate reader. |
$249.00 |
|
|
CA-C149 |
Caspase 9 Assay Kit Fluorescence) - 2 plates (96-well)
Description: Caspase 9 is proven to
have selectivity for the peptide sequence Leu-Glu-His-Asp (LEHD).
This kit uses (Ac-LEHD)2-R110 as a fluorogenic indicator for
caspase 9 activity. Cleavage of R110 peptides by caspase 9
generates strongly fluorescent rhodamine 110 (R110) which is
monitored at the emission between 520 nm and 530nm with the
excitation between 480 nm and 500 nm.
Application:
The
Elite™
Caspase 8 Assay Kit provides all the essential components.
The assay is robust and can be readily adapted for high
throughput screening. It can be used to either quantify the
activated caspase 9 activities in apoptotic cells or screen
the caspase 9 inhibitors. Quite a few labs have used this
kit for high throughput screening.
Detection:
Fluorescence microplate
microplate reader. |
$325.00 |
|
| CA-C066 |
Cell Cytotoxicity Assay Kit (Red Fluorescence) - 100 assays (96-well plates)
Description: It is more sensitive for cell
proliferation and cytotoxicity than other assays such as MTT.
The kit components are quite stable with minimal
cytotoxicity, thus a longer incubation time (such as 24 to
48 hours) is possible if required.
Application: Excellent for high
throughput screening of cell proliferation or cytotoxicity
against a variety of compounds.
Ex/Em: 540/590 nm.
Detection: Fluorescence microplate
reader. |
$199.00 |
|
|
CA-C093 |
Apoptosis Assay Kit(Green Fluorescence) - 100 assays
Description: Compared to Annexin V,
the Apopxin™ PS sensor used in this kit is reengineered to
have a much higher affinity to PS with Kd < 10 nM. The PS
sensor has green fluorescence upon binding to membrane PS.
The fluorescent sensor has Ex/Em = 490/520 nm, making assay
readily run with FITC filter set.
Application:
It can be
used with a fluorescence microplate reader besides the
microscope and flow cytometry platforms. HTS applications.
Ex/Em: 490/520 nm.
Detection: Flow cytometer. |
$199.00 |
|
| CA-C095 |
Apoptosis Assay Kit (Optimized for Flow Cytometric Applications) - 100 assays
Description: Compared to Annexin V, the Apopxin™ PS
sensor used in this kit is reengineered to have a much
higher affinity to PS with Kd < 10 nM. The PS sensor has
green fluorescence upon binding to membrane PS. The
fluorescent sensor has Ex/Em = 490/520 nm, making assay
readily run with FITC filter set.
Application: It is optimized for
flow cytometric applications
Ex/Em: 490/520 nm.
Detection: Flow cytometer. |
$199.00 |
|
|
CA-C106 |
Cell Cycle Assay Kit(Green Fluorescence) - 100 assays
Description: This kit is designed
to monitor cell cycle progression and proliferation by using
our proprietary Nuclear Green™ LCS1 in permeabilized and
fixed cells.
Application:
It is optimized
for flow cytometric applications.
Ex/Em: 490/520 nm.
Detection: Flow cytometer. |
$199.00 |
|
| CA-C112 |
Cell Viability Assay Kit (Green Fluorescence) - 5 plates (96-well)
Description: This kit uses a proprietary green
fluorescent dye that easily permeates intact live cells and
gets enhanced fluorescence upon entering into live cells.
The hydrolysis of the non-fluorescent substrate by
intracellular esterases generates a strongly green
fluorescent hydrophilic product that is well-retained in the
cell cytoplasm.
Application: It is useful for a
variety of studies, including cell adhesion, chemotaxis,
multidrug resistance, cell viability, apoptosis and
cytotoxicity. The kit is suitable for proliferating and
non-proliferating cells.
Ex/Em: 490/520 nm.
Detection: Fluorescence microplate
reader. |
$199.00 |
|
|
CA-C124 |
Live Cell Labeling Kit(Green Fluorescence) - 10 plates (96-well)
Description: This Kit is designed to
uniformly label live cells with a non-fluorescent Calcein
Green™ that becomes strongly fluorescent upon entering into
live cells.
Application:
It can be
readily adapted for a wide variety of fluorescence platforms
such as microplate assays, flow cytometry and fluorescence
microscope. It is useful for a variety of studies, including
cell adhesion, chemotaxis, multidrug resistance, cell
viability, apoptosis and cytotoxicity.
Ex/Em: 490/520 nm.
Detection: Fluorescence microscope |
$299.00 |
|
| CA-A115 |
Cell Growth Assay Kit (luminescence) - 100 assays in 96-well plates
Description: The Elite™ Cell Assay Kit is designed
to gauge cell growth by measuring proportional changes in
total cell ATP. This is a homogenous assay, which can be
performed on multi-well plates by adding the reagents
directly to cell growth medium in both adherent and
suspension cell cultures.
Application: This assay has been
optimized to accurately measure cell number over a broad
dynamic range (102 - 2x105 cells) in 96-well plate format,
ideal for automated high-throughput screening. The assay
accurately monitors cell growth over time periods from 24 –
120 h, and the ATP detection sensitivity is from 0.1 to 1000
µM. For cell proliferation, cell toxicity, and ATP
measurement.
Detection: Microplate luminometer. |
$195.00 |
|
|
CA-C315 |
cAMP ELISA Assay Kit(Fluorescence) - 1 plate (96-well)
Description: Elite™ cAMP ELISA
Assay Kit provides the sensitive method for detecting
adenylate cyclase activity in biochemical or cell-based
assay system. Compared to other ELISA cAMP assay kits, our
kit eliminates the tedious acetylation step. The kit uses
Amplite™ Red as a fluorimetric substrate to quantify the HRP
activity.
Application:
The assay can be
performed in a convenient 96-well or 384-well microtiter-plate
format and easily adapted to automation. The fluorescent
product formed is proportional to the activity of HRP-cAMP
conjugate.
Detection: Fluorescence microplate
reader. |
$299.00 |
|
| CA-M145 |
Mitochondrial Membrane Potential Kit - 500 assays in 96-well plates
Description: Mitochondrial membrane potential (Δψm)
is an important parameter of mitochondrial function used as
an indicator of cell health. EliteTM Mitochondrial Membrane
Potential Detection Kit provides all the necessary reagents
for the analysis of mictochondrial integrity in cells. The
aggregate red form has absorption/emission maxima of 585/590
nm. The green monomeric form has absorption/ emission maxima
of 510/527 nm.
Application: The assay is
applicable to flow cytometry, fluorescence microscopy, and
96-well plate formats.
Detection: Microplate reader. |
$395.00 |
|
-
Ordering Instructions -
|
|
|
Partnerships |
| |
JNetDirect
Biosciences
is looking to represent developers and manufacturers
to provide a complete solution to biotech
scientists.
More info - Contact Us!
|
|