Porti System
Stationary & Ambulatory System for EEG or Polysomnography

Versatile, scalable, unsurpassed signal quality

 

The Porti is a multi-channel ambulatory and stationary system for physiological research. The Porti can have unipolar electrophysiological inputs (ExG), bipolar electro-physiological inputs (BIP) and auxiliary inputs (AUX). The unipolar electro-physiological inputs are configured as a reference amplifier: all channels are amplified against the average of all connected inputs. Using these channels, signals like: EEG, EMG, ECG, EOG, EGG etc. can be measured. The bipolar electro-physiological inputs are used to measure two physiological signals differentially to each other. Signals like ECG, EMG or EOG can be measured this way. The auxiliary inputs can be used for measuring sensor signals like temperature, pH, respiration, movements, force, angle, etc. Each of these channels has a +5V and -5V output in order to use active sensors or sensor modules. For the measurement of oxygen saturation a special serial input is available. A digital trigger input can also be included.

 

The Porti system can be equipped having different number of input channels. Porti's with 8, 16, 24 and 32 channels are available.

 

The Porti can be used for both stationary as well as ambulatory measurements. In stationary setup an external power supply, which plugs into the mains socket, powers the Porti. The Porti is connected to a PC by means of a bi-directional glass fiber. It is also possible to use the built-in BlueTooth telemetry to send the data directly to a PC, a PDA or a mobile phone. Please note that the bandwidth may be limited when using the telemetry option. When the Porti is used ambulatory, it is always powered by batteries. Measured data is written to a flash disk. After a recording is ended a PC or notebook reads out the memory card, making the measurement data available for further analysis.

 

The design of the Porti integrates the true DC reference amplifier. The active shielding guarantees optimal signal quality, no mains or other interference and complete absence of movement artifacts. Since the system includes no hardware filtering, all amplifier channels are identical and can be used for any desired signal.

 

The Porti can be carried in a pouch on the subject's belt and is powered by 6 or 12 AA batteries in ambulatory mode.

>>Download Porti Brochure

bulletno movement artifacts
bulletfrom DC to maximum sample frequency
bulletup to 32 channels  front-end
bulletdigital input for SpO2
bullet24 hours recording
bulletup to 1 Gbyte internal storage
bulletBluetooth® telemetry
bulletPCMCIA slot for flash disk
bulletBattery compartment for 6 or 12x AA batteries
bulletMaximum sample rate 2000 or 2048 Hz

 

Included accessories:

bulletOptical fiber 10m
bulletFUSBI Fiber-USB converter
bulletMedical power supply
bulletSuitcase
bulletCarrying bag
bulletDrivers for Windows Xp and Vista 32 bits
bulletEnglish manual
bulletCE- certification
bullet2x patient ground cable 1,5m/each

 

Product Specifications:

 

bullet

CE0044: This device meets all the requirements of the MDD (93/42/EEC) MDD Classification  IIa (rule 10)

bullet

Applied standards:

IEC 60601-1:1988 + A1:1991 + A2:1995 : Medical electrical equipment - Part 1: General requirements for safety

IEC 60601-1-2:2001 : Medical electrical equipment - Part 1-2: Electromagnetic compatibility

bullet

Safety class (IEC 60601-1): Internally or externally powered, type CF

bullet

External Dimensions: 158 x 112 x 53 mm (l x w x h)

 

Internal Power Supply:

bulletBatteries: 6 or 12 x AA type rechargeable NiCd or NiMH 1.2V or disposable alkaline 1.5V
bulletBattery low indication level: 6.2 V ± 0.1V
bulletBattery empty shut down level: 5.9 V ± 0.1V

 

Unipolar ExG inputs (EEG, ECG, EOG, EMG etc.):

bulletNoise: < 2 µVpp (@ Fs = 128 Hz)
bulletGain: 20 x
bulletInput signal difference: < 0.15 V
bulletInput common mode range: -2V - +2V
bulletInput impedance: > 1012 W
bulletCMRR: > 100 dB
bulletConnector: micro coax, active shielding

 

Bipolar ExG inputs (EEG, ECG, EOG, EMG etc.):

bulletNoise: < 2 µVpp (@ Fs = 128 Hz)
bulletGain: 20 x
bulletInput signal difference: < 0.15 V
bulletInput common mode range: -2V - +2V
bulletInput impedance: > 1012 W
bulletCMRR: > 100 dB
bulletConnector: 4 pin BINDER 719 series

 

AUX inputs

bulletNoise: < 20 µV pp (@ Fs = 128 Hz)
bulletGain: 1 x
bulletInput signal range (diff.): -3V - +3V
bulletInput common mode range: -4V - +4V
bulletInput impedance: > 1010 W
bulletCMRR: > 70 dB
bulletOutput voltage: + 5V, -5V, max 5mA per channel, or 40 mA for all channels together
bulletConnector: 5 pin BINDER 719 series

 

Sampling:

bulletResolution: 22 bits, ExG 71.526 nV per bit, AUX 1.4305 µV per bit
bulletSample frequency (Fs):
bullet2048 Hz, 1024 Hz, 512 Hz, 256 Hz, 128 Hz or:
bullet2000 Hz. 1000 Hz, 500 Hz, 250 Hz, 125 Hz or:
bullet1600 Hz, 800 Hz, 400 Hz, 200 Hz, 100 Hz


Filtering/gain:

bulletGain: ExG 20 x, fixed (= 50 mV/V),
bulletBIP 20 x, fixed (= 50 mV/V),
bulletAUX 1 x, fixed (= 1 V/V)
bulletHigh pass: none
bulletLow pass: digital FIR filter in ADC, cutoff frequency = 0.27 * sample frequency


Bluetooth communication:

bulletBluetooth: 1.1 class 2
bulletUsed profile: Serial port profile
bulletLine of sight range: > 10 meter
bulletBaud rate: 230400 bps


Fiber communication:

bulletBit rate: 7.168 Mbit/s
bulletMax supported sample rate: 2048 Hz
bulletFiber length: up to 100m
bulletRequired interface: FUSBI, requires USB1.1 or USB2.0 port on PC

 

Possible configurations (other configurations on request)

Number of channels Number of unipolar channels Number of bipolar channels Number of AUX channels Saturation input available Housing size
8 8 - - - Small
8 - 8 - - Small
8 - - 8 - Small
16 16 - - - Small
16 - 16 - - Small
16 - - 16 - Small
16 8 4 4 - Small
16 8 4 3 yes Small
16 8 - 8 - Small
16 - 8 8 - Small
16 - 8 7 yes Small
24 24 - - - Large
24  - 16 8 - Large
32 32 - - - Large
32 - 24 8 - Large
32 - 24 7 yes Large
32 24 4 4 - Large
32 24 4 3 yes Large

 

 

- Ordering Instructions -

 

Upon receiving your order, a customer service representative will contact you
to confirm the desired configuration.

# Description   Price ($US) Quantity
Porti-8-2000 8 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2000 Hz

$11,470


Porti-8-2048 8 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2048 Hz

$11,470


Porti-16-2000 16 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2000 Hz

$13,350


Porti-16-2048 16 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2048 Hz

$13,350


Porti-24-2000 24 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2000 Hz

$15,700


Porti-24-2048 24 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2048 Hz

$15,700


Porti-32-2000 32 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2000 Hz

$17,750


Porti-32-2048 32 Channels Porti Ambulatory / Stationary System

Max. samples rate: 2048 Hz

$17,750


# Optional Item   Price ($US) Quantity
Porti-trigger Isolated External Trigger Input $150


 

- Ordering Instructions -

 

 

 

 

 

 

      Catalog
 

View/Download
the new
JNetDirect Biosciences
Products Overview


 

      Partnerships
 

JNetDirect Biosciences
is looking
to represent developers and manufacturers to provide a complete solution to biotech scientists.

More info - Contact Us!

     
 

 Back Home Up Next

 
Copyright © 2003-2011 -  JNetDirect Biosciences  / Privacy Statement